[CVE_SUBSCRIPTIONS]

Receive alerts for specific vendors, products, or severities

📡 [FLUX RSS CVE]

Subscribe to the CVE feed

7 derniers jours

> FILTERS

> Last 7 Days

STATISTIQUES

Total CVE: 429339
> CVE-2021-40416 [HIGH 8.8]
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. All the Get APIs that are not included in cgi_check_ability are already executable by any logged-in users. An attacker can send an HTTP request to trigge...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40415 [MEDIUM 6.5]
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. In cgi_check_ability the Format API does not have a specific case, the user permission will default to 7. This will give non-administrative users the pos...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40414 [HIGH 7.1]
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. The SetMdAlarm API sets the movement detection parameters, giving the ability to set the sensitivity of the camera per a range of hours, and which of the...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40413 [HIGH 7.1]
An incorrect default permission vulnerability exists in the cgiserver.cgi cgi_check_ability functionality of reolink RLC-410W v3.0.0.136_20121102. The UpgradePrepare is the API that checks if a provided filename identifies a new version of the RLC-410W firmware. If the version is new, it would be po...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40412 [HIGH 7.2]
An OScommand injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [8] the devname variable, that has the value of the name parameter provided through the SetDevName API, is not validated properly. This would lead to an OS command inj...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40411 [HIGH 7.2]
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [6] the dns_data->dns2 variable, that has the value of the dns2 parameter provided through the SetLocalLink API, is not validated properly. This would lead to an OS c...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40410 [HIGH 7.2]
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [4] the dns_data->dns1 variable, that has the value of the dns1 parameter provided through the SetLocal API, is not validated properly. This would lead to an OS comma...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40409 [CRITICAL 9.8]
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->password variable, that has the value of the password parameter provided through the SetDdns API, is not validated properly....
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40408 [CRITICAL 9.8]
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->username variable, that has the value of the userName parameter provided through the SetDdns API, is not validated properly....
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40407 [HIGH 7.2]
An OS command injection vulnerability exists in the device network settings functionality of reolink RLC-410W v3.0.0.136_20121102. At [1] or [2], based on DDNS type, the ddns->domain variable, that has the value of the domain parameter provided through the SetDdns API, is not validated properly. Thi...
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40406 [HIGH 7.5]
A denial of service vulnerability exists in the cgiserver.cgi session creation functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to prevent users from logging in. An attacker can send an HTTP request to trigger this vulnerability.
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40404 [MEDIUM 6.5]
An authentication bypass vulnerability exists in the cgiserver.cgi Login functionality of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted HTTP request can lead to authentication bypass. An attacker can send an HTTP request to trigger this vulnerability.
AFFECTED_PRODUCTS: Reolink Rlc 410w Firmware
> CVE-2021-40397 [HIGH 7.8]
A privilege escalation vulnerability exists in the installation of Advantech WISE-PaaS/OTA Server 3.0.9. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability.
AFFECTED_PRODUCTS: Advantech Wise Paas\/ota
> CVE-2021-40396 [HIGH 8.8]
A privilege escalation vulnerability exists in the installation of Advantech DeviceOn/iService 1.1.7. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability.
AFFECTED_PRODUCTS: Advantech Deviceon\/iservice
> CVE-2021-40389 [HIGH 8.8]
A privilege escalation vulnerability exists in the installation of Advantech DeviceOn/iEdge Server 1.0.2. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability.
AFFECTED_PRODUCTS: Advantech Deviceon\/iedge
> CVE-2021-40388 [HIGH 8.8]
A privilege escalation vulnerability exists in Advantech SQ Manager Server 1.0.6. A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability.
AFFECTED_PRODUCTS: Advantech Sq Manager
> CVE-2021-40340 [LOW 3.7]
Information Exposure vulnerability in Hitachi Energy LinkOne application, due to a misconfiguration in the ASP server exposes server and ASP.net information, an attacker that manages to exploit this vulnerability can use the exposed information as a reconnaissance for further exploitation. This issu...
AFFECTED_PRODUCTS: Hitachi Linkone, Hitachi Linkone, Hitachi Linkone ... (+3)
> CVE-2021-40339 [LOW 3.7]
Configuration vulnerability in Hitachi Energy LinkOne application due to the lack of HTTP Headers, allows an attacker that manages to exploit this vulnerability to retrieve sensitive information. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25; 3.26.
AFFECTED_PRODUCTS: Hitachi Linkone, Hitachi Linkone, Hitachi Linkone ... (+3)
> CVE-2021-40338 [LOW 3.7]
Hitachi Energy LinkOne product, has a vulnerability due to a web server misconfiguration, that enables debug mode and reveals the full path of the filesystem directory when an attacker generates errors during a query operation. This issue affects: Hitachi Energy LinkOne 3.20; 3.22; 3.23; 3.24; 3.25;...
AFFECTED_PRODUCTS: Hitachi Linkone, Hitachi Linkone, Hitachi Linkone ... (+3)
> CVE-2021-31567 [MEDIUM 6.8]
Authenticated (admin+) Arbitrary File Download vulnerability discovered in Download Monitor WordPress plugin (versions <= 4.4.6). The plugin allows arbitrary files, including sensitive configuration files such as wp-config.php, to be downloaded via the &downloadable_file_urls[0] parameter data. It's...
AFFECTED_PRODUCTS: Wpchill Download Monitor
> CVE-2021-27654 [HIGH 7.8]
Forgotten password reset functionality for local accounts can be used to bypass local authentication checks.
AFFECTED_PRODUCTS: Pega Infinity
> CVE-2021-26264 [MEDIUM 6.1]
A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition.
> CVE-2021-23863 [MEDIUM 6.1]
HTML code injection vulnerability in Android Application, Bosch Video Security, version 3.2.3. or earlier, when successfully exploited allows an attacker to inject random HTML code into a component loaded by WebView, thus allowing the Application to display web resources controlled by the attacker.
AFFECTED_PRODUCTS: Bosch Video Security
> CVE-2021-23174 [LOW 3.4]
Authenticated (admin+) Persistent Cross-Site Scripting (XSS) vulnerability discovered in Download Monitor WordPress plugin (versions <= 4.4.6) Vulnerable parameters: &post_title, &downloadable_file_version[0].
AFFECTED_PRODUCTS: Wpchill Download Monitor
> CVE-2021-22827 [HIGH 8.8]
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
AFFECTED_PRODUCTS: Schneider Electric Ecostruxure Power Monitoring Expert
> CVE-2021-22826 [HIGH 8.8]
A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions
AFFECTED_PRODUCTS: Schneider Electric Ecostruxure Power Monitoring Expert
> CVE-2021-22825 [HIGH 8.0]
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could allow an attacker to access the system with elevated privileges when a privileged account clicks on a malicious URL that compromises the security token. Affected Products: AP7xxxx and AP8xxx with NM...
AFFECTED_PRODUCTS: Schneider Electric Rack Power Distribution Unit With Network Management Card 2 Firmware, Schneider Electric Rack Power Distribution Unit With Network Management Card 3 Firmware
> CVE-2021-22822 [MEDIUM 6.1]
A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the chargin...
AFFECTED_PRODUCTS: Schneider Electric Evlink City Evc1s22p4 Firmware, Schneider Electric Evlink City Evc1s7p4 Firmware, Schneider Electric Evlink Parking Evw2 Firmware ... (+3)
> CVE-2021-22821 [HIGH 8.6]
A CWE-918 Server-Side Request Forgery (SSRF) vulnerability exists that could cause the station web server to forward requests to unintended network targets when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All ver...
AFFECTED_PRODUCTS: Schneider Electric Evlink City Evc1s22p4 Firmware, Schneider Electric Evlink City Evc1s7p4 Firmware, Schneider Electric Evlink Parking Evw2 Firmware ... (+3)
> CVE-2021-22820 [CRITICAL 9.8]
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 /...
AFFECTED_PRODUCTS: Schneider Electric Evlink City Evc1s22p4 Firmware, Schneider Electric Evlink City Evc1s7p4 Firmware, Schneider Electric Evlink Parking Evw2 Firmware ... (+3)
> CVE-2021-22819 [MEDIUM 4.3]
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All v...
AFFECTED_PRODUCTS: Schneider Electric Evlink City Evc1s22p4 Firmware, Schneider Electric Evlink City Evc1s7p4 Firmware, Schneider Electric Evlink Parking Evw2 Firmware ... (+3)
> CVE-2021-22818 [HIGH 7.5]
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to gain unauthorized access to the charging station web interface by performing brute force attacks. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3....
AFFECTED_PRODUCTS: Schneider Electric Evlink City Evc1s22p4 Firmware, Schneider Electric Evlink City Evc1s7p4 Firmware, Schneider Electric Evlink Parking Evw2 Firmware ... (+3)
> CVE-2021-22816 [HIGH 7.5]
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a Denial of Service of the RTU when receiving a specially crafted request over Modbus, and the RTU is configured as a Modbus server. Affected Products: SCADAPack 312E, 313E, 314E, 330E, 333E, 334E,...
AFFECTED_PRODUCTS: Schneider Electric Scadapack 312e Firmware, Schneider Electric Scadapack 313e Firmware, Schneider Electric Scadapack 314e Firmware ... (+6)
> CVE-2021-22815 [MEDIUM 5.3]
A CWE-200: Information Exposure vulnerability exists which could cause the troubleshooting archive to be accessed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, A...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22814 [MEDIUM 6.1]
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists which could cause arbritrary script execution when a malicious file is read and displayed. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS,...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22813 [MEDIUM 6.1]
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22812 [MEDIUM 6.1]
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC. Affected Products: 1-Phase Uninterruptible Power Supp...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22811 [MEDIUM 6.1]
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause script execution when the request of a privileged account accessing the vulnerable web page is intercepted. Affected Products: 1-Phase Uninterruptible Power Supply (UP...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22810 [MEDIUM 6.1]
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to a delete policy file. Affected Products: 1...
AFFECTED_PRODUCTS: Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 2 Firmware, Schneider Electric Network Management Card 3 Firmware ... (+1)
> CVE-2021-22809 [MEDIUM 5.5]
A CWE-125:Out-of-Bounds Read vulnerability exists that could cause unintended data disclosure when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
AFFECTED_PRODUCTS: Schneider Electric Guicon
> CVE-2021-22808 [HIGH 7.8]
A CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
AFFECTED_PRODUCTS: Schneider Electric Guicon
> CVE-2021-22807 [HIGH 7.8]
A CWE-787: Out-of-bounds Write vulnerability exists that could cause arbitrary code execution when a malicious *.gd1 configuration file is loaded into the GUIcon tool. Affected Product: Eurotherm by Schneider Electric GUIcon Version 2.0 (Build 683.003) and prior
AFFECTED_PRODUCTS: Schneider Electric Guicon
> CVE-2021-22799 [LOW 3.8]
A CWE-331: Insufficient Entropy vulnerability exists that could cause unintended connection from an internal network to an external network when an attacker manages to decrypt the SESU proxy password from the registry. Affected Product: Schneider Electric Software Update, V2.3.0 through V2.5.1
AFFECTED_PRODUCTS: Schneider Electric Software Update
> CVE-2021-22725 [HIGH 8.8]
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P...
AFFECTED_PRODUCTS: Schneider Electric Evc1s22p4 Firmware, Schneider Electric Evc1s7p4 Firmware, Schneider Electric Evw2 Firmware ... (+3)
> CVE-2021-22724 [HIGH 8.8]
A CVE-352 Cross-Site Request Forgery (CSRF) vulnerability exists that could allow an attacker to impersonate the user or carry out actions on their behalf when crafted malicious parameters are submitted in POST requests sent to the charging station web server. Affected Products: EVlink City EVC1S22P...
AFFECTED_PRODUCTS: Schneider Electric Evc1s22p4 Firmware, Schneider Electric Evc1s7p4 Firmware, Schneider Electric Evw2 Firmware ... (+3)
> CVE-2016-3735 [HIGH 8.1]
Piwigo is image gallery software written in PHP. When a criteria is not met on a host, piwigo defaults to usingmt_rand in order to generate password reset tokens. mt_rand output can be predicted after recovering the seed used to generate it. This low an unauthenticated attacker to take over an accou...
AFFECTED_PRODUCTS: Piwigo Piwigo
> CVE-2022-22868 [MEDIUM 4.8]
Gibbon CMS v22.0.01 was discovered to contain a cross-site scripting (XSS) vulnerability, that allows attackers to inject arbitrary script via name parameters.
AFFECTED_PRODUCTS: Gibbonedu Gibbon
> CVE-2021-44971 [CRITICAL 9.8]
Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE.
AFFECTED_PRODUCTS: Tenda Ac15 Firmware, Tenda Ac5 Firmware
> CVE-2021-41609 [CRITICAL 9.8]
SQL injection in the ID parameter of the UploadedImageDisplay.aspx endpoint of SelectSurvey.NET before 5.052.000 allows a remote, unauthenticated attacker to retrieve data from the application's backend database via boolean-based blind and UNION injection.
AFFECTED_PRODUCTS: Classapps Selectsurvey.net
> CVE-2021-41608 [HIGH 7.5]
A file disclosure vulnerability in the UploadedImageDisplay.aspx endpoint of SelectSurvey.NET before 5.052.000 allows a remote, unauthenticated attacker to retrieve survey user submitted data by modifying the value of the ID parameter in sequential order beginning from 1.
AFFECTED_PRODUCTS: Classapps Selectsurvey.net