> CVE-2026-93338 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2026-09-18 17:17
MODIFIED
2026-09-18 17:17
CVSS_SCORE V3
6.9
EPSS (Prob. Exploit)
0.53%
Top 56.3%
DATA SOURCES:
NVD 🔗 2026-09-18 CWE MITRE 🔗 2026-10-01 FIRST EPSS 🔗 2026-10-16

> DESCRIPTION

Grandstream GWN7660ELR before firmware version 1.0.27.6 contains an information disclosure vulnerability that allows unauthenticated remote attackers to obtain sensitive system information by querying the SNMP v2c service configured with the default community string 'public'. Attackers can query standard MIBs over the SNMP port to retrieve operating system and kernel version, running process names and command-line arguments, network interface configuration, routing table entries, ARP table mappings, active TCP connection details, and file system paths, enabling detailed reconnaissance of the device and adjacent network infrastructure.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
None
Aucune interruption de service

> WEAKNESSES

CWE-1188

> CWE DETAILED DESCRIPTIONS

CWE-1188: Initialization of a Resource with an Insecure Default - The product initializes or sets a resource with a default that is intended to be changed by the product's installer, administrator, or maintainer, but the default is not secure.

> HISTORIQUE DES MODIFICATIONS

Première apparition
18/09/2026 17:17
Source: NVD
📊 ENRICHISSEMENT 01/10/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-1188: Initialization of a Resource with an Insecure Default - The product initializes or sets a resource with a default that is intended to be changed by the product's installer, administrator, or...
Total des modifications: 1 Dernière mise à jour: 3 weeks ago

> REFERENCES

https://firmware.grandstream.com/BETA/Release_Note_GWN7660ELR_7665_1.0.27.6.pdf
https://www.grandstream.com/support/firmware
https://www.vulncheck.com/advisories/grandstream-gwn7660elr-information-disclosu...
« BACK_TO_HOME