A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
| Métrique | Valeur | Interprétation |
|---|---|---|
|
AV (Vecteur d'Attaque)
Attack Vector
|
Network (N)
|
Exploit possible à distance via réseau (HTTP, API, etc.) |
|
AC (Complexité d'Attaque)
Attack Complexity
|
Low (L)
|
Peu de conditions requises pour exploiter |
|
PR (Privilèges Requis)
Privileges Required
|
None (N)
|
Aucune authentification requise |
|
UI (Interaction Utilisateur)
User Interaction
|
None (N)
|
Aucune interaction utilisateur nécessaire |
|
S (Périmètre)
Scope
|
Unchanged (U)
|
Impact reste dans le périmètre du composant compromis |
|
C (Impact Confidentialité)
Confidentiality Impact
|
Low (L)
|
Divulgation limitée d'informations |
|
I (Impact Intégrité)
Integrity Impact
|
None (N)
|
Aucune modification de données possible |
|
A (Impact Disponibilité)
Availability Impact
|
None (N)
|
Aucune interruption de service |