> CVE-2026-46716 [CRITICAL]

« BACK_TO_HOME
PUBLISHED
2026-06-12 22:16
MODIFIED
2026-06-12 22:16
CVSS_SCORE V3
9.9
EPSS (Prob. Exploit)
0.43%
Top 62.7%
DATA SOURCES:
NVD đź”— 2026-06-12 CWE MITRE đź”— 2026-11-01 FIRST EPSS đź”— 2026-11-01 GITHUB đź”— 2026-10-29 OSV đź”— 2026-11-02

> DESCRIPTION

Nezha Monitoring is a self-hostable, lightweight, servers and websites monitoring and O&M tool. From version 1.4.0 to before version 2.0.8, a RoleMember user can create a scheduled cron task with Cover=CronCoverAll, Servers=[] and an arbitrary Command. At every tick of the scheduler, the dashboard pushes that command to every server in the global ServerShared map — including servers that belong to other tenants (admin's servers, other members' servers). Each agent runs the command and returns the output, which is then sent to the attacker's own NotificationGroup → attacker-controlled webhook. This issue has been patched in version 2.0.8.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
EXPLOITABILITY
3.1
IMPACT
6.0

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
Low (L)
Authentifié avec compte utilisateur basique
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Changed (C)
Impact s'étend au-delà du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
High
Interruption totale du service possible

> WEAKNESSES

CWE-78 CWE-269 CWE-862

> CWE DETAILED DESCRIPTIONS

CWE-78: Improper Neutralization of Special Elements used in an OS Command - The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component. | CWE-269: Improper Privilege Management - The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor. | CWE-862: Missing Authorization - The product does not perform an authorization check when an actor attempts to access a resource or perform an action.

> GITHUB SECURITY ADVISORY

GHSA-99gv-2m7h-3hh9 CRITICAL

Nezha Monitoring: RoleMember can run shell on every server (cross-tenant RCE) via POST /api/v1/cron

AFFECTED PACKAGES:
GO / github.com/nezhahq/nezha
>= 1.4.0, < 1.14.15-0.20260517022419-d7526351cf97
Fixed in: 1.14.15-0.20260517022419-d7526351cf97

> OSV (GOOGLE OPEN SOURCE VULNERABILITIES)

Nezha Monitoring: RoleMember can run shell on every server (cross-tenant RCE) via POST /api/v1/cron

AFFECTED PACKAGES:
Unknown / Unknown
96 versions affected
ALIASES:
GHSA-99gv-2m7h-3hh9, GO-2026-5282

> HISTORIQUE DES MODIFICATIONS

Première apparition
12/06/2026 22:16
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:59
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') - The product constructs all or part of an OS command using externally-influenced input from an upstr...
Nouvelle valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command - The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it doe...
📊 ENRICHISSEMENT 01/07/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') - The product constructs all or part of an OS command using externally-influenced input from an upstr...
Total des modifications: 2 Dernière mise à jour: 6 days ago

> REFERENCES

https://github.com/nezhahq/nezha/security/advisories/GHSA-99gv-2m7h-3hh9
« BACK_TO_HOME