> CVE-2026-38743

« BACK_TO_HOME
PUBLISHED
2026-04-24 13:16
MODIFIED
2026-04-24 13:16
EPSS (Prob. Exploit)
0.57%
Top 53.4%
DATA SOURCES:
NVD 🔗 2026-04-24 CWE MITRE 🔗 2026-11-01 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

The authenticated /ui/dags endpoint did not enforce per-DAG access control on embedded Human-in-the-Loop (HITL) and TaskInstance records: a logged-in Airflow user with read access to at least one DAG could retrieve HITL prompts (including their request parameters) and full TaskInstance details for DAGs outside their authorized scope. Because HITL prompts and TaskInstance fields routinely carry operator parameters and free-form context attached to a task, the leak widens visibility of DAG-run data beyond the intended per-DAG RBAC boundary for every authenticated user. Users are recommended to upgrade to version 3.2.1 , which fixes this issue.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> WEAKNESSES

CWE-1220

> CWE DETAILED DESCRIPTIONS

CWE-1220: Insufficient Granularity of Access Control - The product implements access controls via a policy or other feature with the intention to disable or restrict accesses (reads and/or writes) to assets in a system from untrusted agents. However, implemented access controls lack the required granularity

> HISTORIQUE DES MODIFICATIONS

Première apparition
24/04/2026 13:16
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:59
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-1220: Insufficient Granularity of Access Control - The product implements access controls via a policy or other feature with the intention to disable or restrict accesses (reads and/or writes) to ...
Nouvelle valeur:
CWE-1220: Insufficient Granularity of Access Control - The product implements access controls via a policy or other feature with the intention to disable or restrict accesses (reads and/or writes) to ...
📊 ENRICHISSEMENT 01/05/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-1220: Insufficient Granularity of Access Control - The product implements access controls via a policy or other feature with the intention to disable or restrict accesses (reads and/or writes) to ...
Total des modifications: 2 Dernière mise à jour: 1 week ago

> REFERENCES

https://github.com/apache/airflow/pull/64822
https://lists.apache.org/thread/sk2wj0x48o8qb4p7c47gvnhjbm0mg396
« BACK_TO_HOME