> CVE-2026-38142 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2026-07-01 19:16
MODIFIED
2026-07-01 19:16
CVSS_SCORE V3
6.5
EPSS (Prob. Exploit)
1.07%
Top 35.5%
DATA SOURCES:
NVD 🔗 2026-07-01 CWE MITRE 🔗 2026-11-01 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

An unauthenticated command injection vulnerability in the /goform/fast_setting_internet_set endpoint of Tenda AC18 v15.03.05.05 allows attackers to execute arbitrary commands via a crafted payload injected into the mac parameter.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
EXPLOITABILITY
3.9
IMPACT
2.5

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
Low (L)
Modification limitée des données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
Low
Modification limitée des données possible
Disponibilité
None
Aucune interruption de service

> WEAKNESSES

CWE-77

> CWE DETAILED DESCRIPTIONS

CWE-77: Improper Neutralization of Special Elements used in a Command - The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

> HISTORIQUE DES MODIFICATIONS

Première apparition
01/07/2026 19:16
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:59
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') - The product constructs all or part of a command using externally-influenced input from an upstream compone...
Nouvelle valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command - The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not ne...
📊 ENRICHISSEMENT 01/08/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') - The product constructs all or part of a command using externally-influenced input from an upstream compone...
Total des modifications: 2 Dernière mise à jour: 5 days ago

> REFERENCES

https://github.com/longqx223/Tenda-ac-18-V15.03.05.05-/blob/main/Tenda%20AC18%20...
https://github.com/longqx223/Tenda-ac-18-V15.03.05.05-/blob/main/Tenda%20AC18%20...
« BACK_TO_HOME