> DESCRIPTION

The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Local (L)
Exploit nécessite un accès local au système
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
High
Interruption totale du service possible

> WEAKNESSES

CWE-353

> CWE DETAILED DESCRIPTIONS

CWE-353: Missing Support for Integrity Check - The product uses a transmission protocol that does not include a mechanism for verifying the integrity of the data during transmission, such as a checksum.

> HISTORIQUE DES MODIFICATIONS

Première apparition
05/08/2026 21:16
Source: NVD
📊 ENRICHISSEMENT 01/09/2026 06:02
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-353: Missing Support for Integrity Check - The product uses a transmission protocol that does not include a mechanism for verifying the integrity of the data during transmission, such as a checksu...
Total des modifications: 1 Dernière mise à jour: 2 months ago

> REFERENCES

https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bullet...
https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01
https://www.cve.org/CVERecord?id=CVE-2026-17583
« BACK_TO_HOME