> CVE-2026-15570 [HIGH]

« BACK_TO_HOME
PUBLISHED
2026-08-07 14:16
MODIFIED
2026-08-07 14:16
CVSS_SCORE V3
7.1
EPSS (Prob. Exploit)
0.26%
Top 82.4%
DATA SOURCES:
NVD 🔗 2026-08-07 CWE MITRE 🔗 2026-11-01 FIRST EPSS 🔗 2026-11-01

> DESCRIPTION

An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Adjacent (A)
Exploit nécessite un accès au segment réseau local
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
Low (L)
Interruption partielle du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
Low
Interruption partielle du service possible

> WEAKNESSES

CWE-918

> CWE DETAILED DESCRIPTIONS

CWE-918: Server-Side Request Forgery - The web server receives a URL or similar request from an upstream component and retrieves the contents of this URL, but it does not sufficiently ensure that the request is being sent to the expected destination.

> HISTORIQUE DES MODIFICATIONS

Première apparition
07/08/2026 14:16
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:59
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-918: Server-Side Request Forgery (SSRF) - The web server receives a URL or similar request from an upstream component and retrieves the contents of this URL, but it does not sufficiently ensure th...
Nouvelle valeur:
CWE-918: Server-Side Request Forgery - The web server receives a URL or similar request from an upstream component and retrieves the contents of this URL, but it does not sufficiently ensure that the ...
📊 ENRICHISSEMENT 01/09/2026 06:02
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-918: Server-Side Request Forgery (SSRF) - The web server receives a URL or similar request from an upstream component and retrieves the contents of this URL, but it does not sufficiently ensure th...
Total des modifications: 2 Dernière mise à jour: 2 days ago

> REFERENCES

https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/...
https://vestelinternational.com/security-advisories
« BACK_TO_HOME