> CVE-2026-1089 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2026-04-21 15:16
MODIFIED
2026-04-21 15:16
CVSS_SCORE V3
6.5
EPSS (Prob. Exploit)
0.23%
Top 86.3%
DATA SOURCES:
NVD đź”— 2026-04-21 CWE MITRE đź”— 2026-11-01 FIRST EPSS đź”— 2026-11-08

> DESCRIPTION

User‑Controlled HTTP Header in Fortra's GoAnywhere MFT prior to version 7.10.0 allows attackers to trigger a DNS lookup, as well as DNS Rebinding and Information Disclosure.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L
EXPLOITABILITY
3.9
IMPACT
2.5

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
Low (L)
Interruption partielle du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
Low
Interruption partielle du service possible

> WEAKNESSES

CWE-74

> CWE DETAILED DESCRIPTIONS

CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component - The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.

> HISTORIQUE DES MODIFICATIONS

Première apparition
21/04/2026 15:16
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:59
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') - The product constructs all or part of a command, data structure, or record using externally...
Nouvelle valeur:
CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component - The product constructs all or part of a command, data structure, or record using externally-influenced in...
📊 ENRICHISSEMENT 01/05/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') - The product constructs all or part of a command, data structure, or record using externally...
Total des modifications: 2 Dernière mise à jour: 1 week ago

> REFERENCES

https://www.fortra.com/security/advisories/product-security/fi-2026-005
« BACK_TO_HOME