The Zephyr PL011 UART driver (drivers/serial/uart_pl011.c) contains an unbounded software loop in pl011_irq_tx_enable() that repeatedly invokes the interrupt-driven application callback while the TX interrupt mask bit (PL011_IMSC_TXIM) is set, to work around the controller's level-transition TX-interrupt behavior. When CTS hardware flow control is enabled (devicetree hw-flow-control or runtime UART_CFG_FLOW_CTRL_RTS_CTS) and the wired serial peer de-asserts CTS, the controller stops draining the TX FIFO; pl011_fifo_fill() then returns 0 on every call while the application still has pending data and therefore never disables the TX interrupt. The loop condition never clears, so the thread that called uart_irq_tx_enable() (e.g. h4_send() in the Bluetooth HCI H4 driver) spins indefinitely, hanging the executing context and stalling the transport — a denial of service (CWE-835). An attacker controlling the device attached to the UART's CTS line can trigger the hang by withholding CTS during transmission. Impact is availability only; there is no memory-safety, confidentiality, or integrity consequence. The vulnerable loop was introduced in commit b783bc8448ef (Feb 2025) and shipped in releases v4.1.0 through v4.4.0. The fix breaks out of the loop when CTS is blocking and arms the CTS modem-status interrupt to resume transmission when CTS re-asserts.
| Métrique | Valeur | Interprétation |
|---|---|---|
|
AV (Vecteur d'Attaque)
Attack Vector
|
Adjacent (A)
|
Exploit nécessite un accès au segment réseau local |
|
AC (Complexité d'Attaque)
Attack Complexity
|
Low (L)
|
Peu de conditions requises pour exploiter |
|
PR (Privilèges Requis)
Privileges Required
|
None (N)
|
Aucune authentification requise |
|
UI (Interaction Utilisateur)
User Interaction
|
None (N)
|
Aucune interaction utilisateur nécessaire |
|
S (Périmètre)
Scope
|
Unchanged (U)
|
Impact reste dans le périmètre du composant compromis |
|
C (Impact Confidentialité)
Confidentiality Impact
|
None (N)
|
Aucune divulgation d'informations |
|
I (Impact Intégrité)
Integrity Impact
|
None (N)
|
Aucune modification de données possible |
|
A (Impact Disponibilité)
Availability Impact
|
High (H)
|
Interruption totale du service possible |
Unbounded TX busy-loop DoS in Zephyr PL011 UART driver under CTS hardware flow control