> CVE-2025-46365 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2025-11-05 17:15
MODIFIED
2025-11-05 17:15
CVSS_SCORE V3
5.3
EPSS (Prob. Exploit)
0.37%
Top 70.3%
DATA SOURCES:
NVD 🔗 2025-11-05 CVE PROJECT 🔗 2026-01-19 CWE MITRE 🔗 2026-11-01 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

Dell CloudLink, versions prior 8.1.1, contain a Command Injection vulnerability which can be exploited by an Authenticated attacker to cause Command Injection on an affected Dell CloudLink.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:N
EXPLOITABILITY
0.8
IMPACT
4.0

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:N/I:H/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Local (L)
Exploit nécessite un accès local au système
AC (Complexité d'Attaque)
Attack Complexity
High (H)
Conditions spécifiques doivent être réunies pour exploiter
PR (Privilèges Requis)
Privileges Required
High (H)
Authentifié avec privilèges administratifs
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Changed (C)
Impact s'étend au-delà du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
None
Aucune interruption de service

> WEAKNESSES

CWE-77

> CWE DETAILED DESCRIPTIONS

CWE-77: Improper Neutralization of Special Elements used in a Command - The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

> HISTORIQUE DES MODIFICATIONS

Première apparition
05/11/2025 17:15
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:58
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') - The product constructs all or part of a command using externally-influenced input from an upstream compone...
Nouvelle valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command - The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not ne...
📊 ENRICHISSEMENT 19/01/2026 17:36
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
📊 ENRICHISSEMENT 01/12/2025 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') - The product constructs all or part of a command using externally-influenced input from an upstream compone...
Total des modifications: 3 Dernière mise à jour: 1 week ago

> REFERENCES

https://www.dell.com/support/kbdoc/en-us/000384363/dsa-2025-374-security-update-...