> CVE-2025-3756 [HIGH]

« BACK_TO_HOME
PUBLISHED
2026-04-13 18:16
MODIFIED
2026-04-13 18:16
CVSS_SCORE V3
7.1
EPSS (Prob. Exploit)
0.18%
Top 92.4%
DATA SOURCES:
NVD đź”— 2026-04-13 CWE MITRE đź”— 2026-11-01 FIRST EPSS đź”— 2026-10-25

> DESCRIPTION

A vulnerability exists in the command handling of the IEC 61850 communication stack included in the product revisions listed as affected in this CVE. An attacker with access to IEC 61850 networks could exploit the vulnera bility by using a specially crafted 61850 packet, forcing the communication interfaces of the PM 877, CI850 and CI868 modules into fault mode or causing unavailability of the S+ Operations 61850 connectivity, resulting in a denial-of-service situation.  The System 800xA IEC61850 Connect is not affected. Note: This vulnerability does not impact on the overall availability and functionality of the S+ Operations node, only the 61850 communication function.     This issue affects AC800M (System 800xA): from 6.0.0x through 6.0.0303.0, from 6.1.0x through 6.1.0031.0, from 6.1.1x through 6.1.1004.0, from 6.1.1x through 6.1.1202.0, from 6.2.0x through 6.2.0006.0; Symphony Plus SD Series: A_0, A_1, A_2.003, A_3.005, A_4.001, B_0.005; Symphony Plus MR (Melody Rack): from 3.10 through 3.52; S+ Operations: 2.1, 2.2, 2.3, 3.3.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Adjacent (A)
Exploit nécessite un accès au segment réseau local
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
High
Interruption totale du service possible

> WEAKNESSES

CWE-1284

> CWE DETAILED DESCRIPTIONS

CWE-1284: Improper Validation of Specified Quantity in Input - The product receives input that is expected to specify a quantity (such as size or length), but it does not validate or incorrectly validates that the quantity has the required properties.

> HISTORIQUE DES MODIFICATIONS

Première apparition
13/04/2026 18:16
Source: NVD
📊 ENRICHISSEMENT 01/05/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-1284: Improper Validation of Specified Quantity in Input - The product receives input that is expected to specify a quantity (such as size or length), but it does not validate or incorrectly valid...
Total des modifications: 1 Dernière mise à jour: 6 months ago

> REFERENCES

https://search.abb.com/library/Download.aspx?DocumentID=7PAA020125&LanguageCode=...
« BACK_TO_HOME