> CVE-2025-14749 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2025-12-16 03:15
MODIFIED
2025-12-16 03:15
CVSS_SCORE V3
5.3
EPSS (Prob. Exploit)
0.79%
Top 43.5%
DATA SOURCES:
NVD đź”— 2025-12-16 CVE PROJECT đź”— 2026-01-19 CWE MITRE đź”— 2026-11-01 FIRST EPSS đź”— 2026-11-08

> DESCRIPTION

A vulnerability was identified in Ningyuanda TC155 57.0.2.0. This impacts an unknown function of the file /onvif/device_service of the component ONVIF PTZ Control Interface. The manipulation leads to improper access controls. The attack requires being on the local network. The exploit is publicly available and might be used. The vendor was contacted early about this disclosure but did not respond in any way.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Adjacent (A)
Exploit nécessite un accès au segment réseau local
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
Low (L)
Modification limitée des données possible
A (Impact Disponibilité)
Availability Impact
Low (L)
Interruption partielle du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
Low
Modification limitée des données possible
Disponibilité
Low
Interruption partielle du service possible

> WEAKNESSES

CWE-266 CWE-284

> CWE DETAILED DESCRIPTIONS

CWE-266: Incorrect Privilege Assignment - A product incorrectly assigns a privilege to a particular actor, creating an unintended sphere of control for that actor. | CWE-284: Improper Access Control - The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.

> HISTORIQUE DES MODIFICATIONS

Première apparition
16/12/2025 03:15
Source: NVD
📊 ENRICHISSEMENT 19/01/2026 17:38
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
📊 ENRICHISSEMENT 01/01/2026 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-266: Incorrect Privilege Assignment - A product incorrectly assigns a privilege to a particular actor, creating an unintended sphere of control for that actor. | CWE-284: Improper Access Control -...
Total des modifications: 2 Dernière mise à jour: 9 months ago

> REFERENCES

https://github.com/pwnpwnpur1n/IoT-advisories/blob/main/TC155-Unauth-PTZ-Remote-...
https://vuldb.com/?ctiid.336522
https://vuldb.com/?id.336522
https://vuldb.com/?submit.707198
« BACK_TO_HOME