Malicious Code Execution Vulnerability in Setting and Operation Application for Lighting Control System MILCO.S Setting Application all versions, MILCO.S Setting Application (IR) all versions, MILCO.S Easy Setting Application (IR) all versions, and MILCO.S Easy Switch Application (IR) all versions allows a local attacker to execute malicious code by having installer to load a malicious DLL. However, if the signer name "Mitsubishi Electric Lighting" appears on the "Digital Signatures" tab of the properties for "MILCO.S Lighting Control.exe", the application is a fixed one. This vulnerability only affects when the installer is run, not after installation. If a user downloads directly from our company website and installs the affected product, there is no risk of malicious code being introduced.
| Métrique | Valeur | Interprétation |
|---|---|---|
|
AV (Vecteur d'Attaque)
Attack Vector
|
Local (L)
|
Exploit nécessite un accès local au système |
|
AC (Complexité d'Attaque)
Attack Complexity
|
High (H)
|
Conditions spécifiques doivent être réunies pour exploiter |
|
PR (Privilèges Requis)
Privileges Required
|
None (N)
|
Aucune authentification requise |
|
UI (Interaction Utilisateur)
User Interaction
|
Required (R)
|
Nécessite une action utilisateur (clic lien, ouverture fichier, etc.) |
|
S (Périmètre)
Scope
|
Unchanged (U)
|
Impact reste dans le périmètre du composant compromis |
|
C (Impact Confidentialité)
Confidentiality Impact
|
High (H)
|
Divulgation totale d'informations |
|
I (Impact Intégrité)
Integrity Impact
|
High (H)
|
Modification totale des données possible |
|
A (Impact Disponibilité)
Availability Impact
|
High (H)
|
Interruption totale du service possible |