Knud from Fraktal.fi has found a flaw in some Axis Network Door Controllers and Axis Network Intercoms when communicating over OSDP, highlighting that the OSDP message parser crashes the pacsiod process, causing a temporary unavailability of the door-controlling functionalities meaning that doors cannot be opened or closed. No sensitive or customer data can be extracted as the Axis device is not further compromised. Please refer to the Axis security advisory for more information, mitigation and affected products and software versions.
| Métrique | Valeur | Interprétation |
|---|---|---|
|
AV (Vecteur d'Attaque)
Attack Vector
|
Adjacent (A)
|
Exploit nécessite un accès au segment réseau local |
|
AC (Complexité d'Attaque)
Attack Complexity
|
Low (L)
|
Peu de conditions requises pour exploiter |
|
PR (Privilèges Requis)
Privileges Required
|
None (N)
|
Aucune authentification requise |
|
UI (Interaction Utilisateur)
User Interaction
|
None (N)
|
Aucune interaction utilisateur nécessaire |
|
S (Périmètre)
Scope
|
Unchanged (U)
|
Impact reste dans le périmètre du composant compromis |
|
C (Impact Confidentialité)
Confidentiality Impact
|
None (N)
|
Aucune divulgation d'informations |
|
I (Impact Intégrité)
Integrity Impact
|
None (N)
|
Aucune modification de données possible |
|
A (Impact Disponibilité)
Availability Impact
|
High (H)
|
Interruption totale du service possible |