> CVE-2022-47375 [HIGH]

« BACK_TO_HOME
PUBLISHED
2023-12-12 12:15
MODIFIED
2024-11-21 07:31
CVSS_SCORE V3
7.5
EPSS (Prob. Exploit)
0.72%
Top 45.7%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-15

> DESCRIPTION

A vulnerability has been identified in SIMATIC PC-Station Plus (All versions), SIMATIC S7-400 CPU 412-2 PN V7 (All versions), SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions), SINAMICS S120 (incl. SIPLUS variants) (All versions < V5.2 SP3 HF15), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions). The affected products do not handle long file names correctly. This could allow an attacker to create a buffer overflow and create a denial of service condition for the device.

> AFFECTED_PRODUCTS

Siemens - Sinamics S120 Firmware
Version: 4.7
Siemens - Sinamics S120 Firmware
Version: 4.8
Siemens - Sinamics S120 Firmware
Version: 4.9
Siemens - Sinamics S120 Firmware
Version: 5.0
Siemens - Sinamics S120 Firmware
Version: 5.1
Siemens - Sinamics S120 Firmware
Version: 5.2
Siemens - 6es7412 2ek07 0ab0 Firmware
Siemens - 6es7414 3em07 0ab0 Firmware
Siemens - 6es7414 3fm07 0ab0 Firmware
Siemens - 6es7416 3es07 0ab0 Firmware
Siemens - 6es7416 3fs07 0ab0 Firmware
Siemens - 6ag1414 3em07 7ab0 Firmware
Siemens - 6ag1416 3es07 7ab0 Firmware
Siemens - Simatic Pc Station Plus Firmware

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
High
Interruption totale du service possible

> HISTORIQUE DES MODIFICATIONS

Première apparition
12/12/2023 12:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:38
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME