> CVE-2022-36077 [HIGH]

« BACK_TO_HOME
PUBLISHED
2022-11-08 07:15
MODIFIED
2024-11-21 07:12
CVSS_SCORE V3
7.2
EPSS (Prob. Exploit)
0.69%
Top 46.7%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-15

> DESCRIPTION

The Electron framework enables writing cross-platform desktop applications using JavaScript, HTML and CSS. In versions prior to 21.0.0-beta.1, 20.0.1, 19.0.11, and 18.3.7, Electron is vulnerable to Exposure of Sensitive Information. When following a redirect, Electron delays a check for redirecting to file:// URLs from other schemes. The contents of the file is not available to the renderer following the redirect, but if the redirect target is a SMB URL such as `file://some.website.com/`, then in some cases, Windows will connect to that server and attempt NTLM authentication, which can include sending hashed credentials.This issue has been patched in versions: 21.0.0-beta.1, 20.0.1, 19.0.11, and 18.3.7. Users are recommended to upgrade to the latest stable version of Electron. If upgrading isn't possible, this issue can be addressed without upgrading by preventing redirects to file:// URLs in the `WebContents.on('will-redirect')` event, for all WebContents as a workaround.

> AFFECTED_PRODUCTS

Electronjs - Electron
< 18.3.7
Electronjs - Electron
>= 19.0.0 < 19.0.11
Electronjs - Electron
>= 20.0.0 < 20.0.1
Electronjs - Electron
Version: 21.0.0

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Changed (C)
Impact s'étend au-delà du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
Low (L)
Interruption partielle du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
Low
Interruption partielle du service possible

> HISTORIQUE DES MODIFICATIONS

Première apparition
08/11/2022 07:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:36
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME