> CVE-2022-2005 [HIGH]

« BACK_TO_HOME
PUBLISHED
2022-08-31 16:15
MODIFIED
2024-11-21 07:00
CVSS_SCORE V3
7.5
EPSS (Prob. Exploit)
0.55%
Top 53.4%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-15

> DESCRIPTION

AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain the login credentials and login as a valid user. This issue affects: AutomationDirect C-more EA9 EA9-T6CL versions prior to 6.73; EA9-T6CL-R versions prior to 6.73; EA9-T7CL versions prior to 6.73; EA9-T7CL-R versions prior to 6.73; EA9-T8CL versions prior to 6.73; EA9-T10CL versions prior to 6.73; EA9-T10WCL versions prior to 6.73; EA9-T12CL versions prior to 6.73; EA9-T15CL versions prior to 6.73; EA9-RHMI versions prior to 6.73; EA9-PGMSW versions prior to 6.73;

> AFFECTED_PRODUCTS

Automationdirect - C More Ea9 T6cl R Firmware
< 6.73
Automationdirect - C More Ea9 T6cl Firmware
< 6.73
Automationdirect - C More Ea9 T7cl R Firmware
< 6.73
Automationdirect - C More Ea9 T7cl Firmware
< 6.73
Automationdirect - C More Ea9 T8cl Firmware
< 6.73
Automationdirect - C More Ea9 T10cl Firmware
< 6.73
Automationdirect - C More Ea9 T10wcl Firmware
< 6.73
Automationdirect - C More Ea9 T12cl Firmware
< 6.73
Automationdirect - C More Ea9 T15cl R Firmware
< 6.73
Automationdirect - C More Ea9 T15cl Firmware
< 6.73
Automationdirect - C More Ea9 Rhmi Firmware
< 6.73
Automationdirect - C More Ea9 Pgmsw Firmware
< 6.73

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
None
Aucune interruption de service

> HISTORIQUE DES MODIFICATIONS

Première apparition
31/08/2022 16:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:35
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME