> CVE-2021-3449 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2021-03-25 15:15
MODIFIED
2024-11-21 06:21
CVSS_SCORE V3
5.9
EPSS (Prob. Exploit)
63.54%
Top 0.8%
⚡ EPSS ÉLEVÉ (63.5%)
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-15

> DESCRIPTION

An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j).

> AFFECTED_PRODUCTS

SonicWall - SonicOS
Version: 7.0.1.0
OpenSSL - OpenSSL
>= 1.1.1 < 1.1.1k
FreeBSD - Freebsd
Version: 12.2
Debian - Debian Linux
Version: 9.0
Debian - Debian Linux
Version: 10.0
Fedoraproject - Fedora
Version: 34
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.57
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.58
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.59
Oracle - Secure Backup
< 18.1.0.1.0
Oracle - Jd Edwards Enterpriseone Tools
< 9.2.6.0
McAfee - Web Gateway
Version: 8.2.19
McAfee - Web Gateway
Version: 9.2.10
McAfee - Web Gateway
Version: 10.1.1
Siemens - Simatic S7 1200 Cpu 1211c Firmware
Siemens - Simatic S7 1200 Cpu 1212c Firmware
Siemens - Simatic S7 1200 Cpu 1212fc Firmware
Siemens - Simatic S7 1200 Cpu 1214 Fc Firmware
Siemens - Simatic S7 1200 Cpu 1214c Firmware
Siemens - Simatic S7 1200 Cpu 1215 Fc Firmware
Siemens - Simatic S7 1200 Cpu 1215c Firmware
Siemens - Simatic S7 1200 Cpu 1217c Firmware
Oracle - Secure Global Desktop
Version: 5.6
Node.js - Node.js
>= 10.0.0 <= 10.12.0
Node.js - Node.js
>= 10.13.0 <= 10.24.0
Node.js - Node.js
>= 12.0.0 <= 12.12.0
Node.js - Node.js
>= 12.13.0 < 12.22.1
Node.js - Node.js
>= 14.0.0 <= 14.14.0
Node.js - Node.js
>= 14.15.0 < 14.16.1
Node.js - Node.js
>= 15.0.0 < 15.14.0
Tenable - Nessus
<= 8.13.1
Siemens - Sinema Server
Version: 14.0
Oracle - Primavera Unifier
>= 17.7 <= 17.12
Oracle - Primavera Unifier
Version: 19.12
Oracle - Primavera Unifier
Version: 20.12
Oracle - Primavera Unifier
Version: 21.12
Tenable - Log Correlation Engine
< 6.0.9
Siemens - Scalance M 800 Firmware
>= 6.2
Siemens - Scalance S615 Firmware
>= 6.2
Siemens - Simatic Logon
>= 1.6.0.2
Siemens - Simatic Logon
Version: 1.5
Oracle - Mysql Workbench
<= 8.0.23
Oracle - Mysql Connectors
<= 8.0.23
Oracle - Jd Edwards World Security
Version: a9.4
Siemens - Scalance W700 Firmware
>= 6.5
Siemens - Scalance Xb 200 Firmware
< 4.3
Siemens - Scalance Xc 200 Firmware
< 4.3
Siemens - Scalance Xp 200 Firmware
< 4.3
Siemens - Scalance Xm 400 Firmware
< 6.4
Oracle - Communications Communications Policy Management
Version: 12.6.0.0.0
Siemens - Tim 1531 Irc Firmware
>= 2.0 < 2.2
Siemens - Scalance Sc 600 Firmware
>= 2.0
Siemens - Simatic Net Cp 1243 1 Firmware
>= 3.1
Siemens - Simatic Net Cp 1243 8 Irc Firmware
>= 3.1
Siemens - Simatic Net Cp 1542sp 1 Irc Firmware
>= 2.1
Siemens - Simatic Net Cp 1543 1 Firmware
>= 2.2 < 3.0
Siemens - Simatic Net Cp 1543sp 1 Firmware
>= 2.1
Siemens - Simatic Rf185c Firmware
Siemens - Simatic Rf186c Firmware
Siemens - Simatic Rf186ci Firmware
Siemens - Simatic Rf188ci Firmware
Siemens - Simatic Hmi Comfort Outdoor Panels Firmware
Siemens - Scalance S602 Firmware
>= 4.1
Siemens - Scalance S612 Firmware
>= 4.1
Siemens - Scalance S623 Firmware
>= 4.1
Siemens - Scalance S627 2m Firmware
>= 4.1
Oracle - Zfs Storage Appliance Kit
Version: 8.8
Oracle - Mysql Server
<= 5.7.33
Oracle - Mysql Server
>= 8.0.15 <= 8.0.23
Tenable - Tenable.sc
>= 5.13.0 <= 5.17.0
Siemens - Simatic Wincc Runtime Advanced
Siemens - Simatic Rf188c Firmware
Siemens - Sinec Nms
Version: 1.0
Siemens - Sinumerik Opc Ua Server
Siemens - Tia Administrator
Oracle - Graalvm
Version: 19.3.5
Oracle - Graalvm
Version: 20.3.1.2
Oracle - Graalvm
Version: 21.0.0.2
Siemens - Scalance Xf 200ba Firmware
< 4.3
Siemens - Scalance Xr 300wg Firmware
< 4.3
Oracle - Essbase
Version: 21.2
Siemens - Simatic Hmi Ktp Mobile Panels Firmware
Siemens - Sinec Infrastructure Network Services
< 1.0.1.1
Siemens - Simatic Net Cp 1545 1 Firmware
>= 1.0
Oracle - Enterprise Manager For Storage Management
Version: 13.4.0.0
Siemens - Simatic Hmi Basic Panels 2nd Generation Firmware
SonicWall - Sma100 Firmware
>= 10.2.0.0 < 10.2.1.0-17sv
Tenable - Nessus Network Monitor
Version: 5.11.0
Tenable - Nessus Network Monitor
Version: 5.11.1
Tenable - Nessus Network Monitor
Version: 5.12.0
Tenable - Nessus Network Monitor
Version: 5.12.1
Tenable - Nessus Network Monitor
Version: 5.13.0
Siemens - Scalance W1700 Firmware
>= 2.0
Siemens - Simatic Mv500 Firmware
McAfee - Web Gateway Cloud Service
Version: 8.2.19
McAfee - Web Gateway Cloud Service
Version: 9.2.10
McAfee - Web Gateway Cloud Service
Version: 10.1.1
Check Point - Quantum Security Management Firmware
Version: r80.40
Check Point - Quantum Security Management Firmware
Version: r81
Check Point - Multi Domain Management Firmware
Version: r80.40
Check Point - Multi Domain Management Firmware
Version: r81
Check Point - Quantum Security Gateway Firmware
Version: r80.40
Check Point - Quantum Security Gateway Firmware
Version: r81
SonicWall - Capture Client
Version: 3.5
Siemens - Ruggedcom Rcm1224 Firmware
>= 6.2
Siemens - Scalance Lpe9403 Firmware
Siemens - Scalance Xr524 8c Firmware
< 6.4
Siemens - Scalance Xr526 8c Firmware
< 6.4
Siemens - Scalance Xr528 6m Firmware
< 6.4
Siemens - Scalance Xr552 12 Firmware
< 6.4
Siemens - Simatic Cloud Connect 7 Firmware
>= 1.1
Siemens - Simatic Cp 1242 7 Gprs V2 Firmware
>= 3.1
Siemens - Simatic Net Cp1243 7 Lte Eu Firmware
>= 3.1
Siemens - Simatic Net Cp1243 7 Lte Us Firmware
>= 3.1
Siemens - Simatic Pcs 7 Telecontrol Firmware
Siemens - Simatic Pcs Neo Firmware
Siemens - Simatic Pdm Firmware
>= 9.1.0.7
Siemens - Simatic Process Historian Opc Ua Server Firmware
>= 2019
Siemens - Simatic Rf166c Firmware
Siemens - Simatic Rf360r Firmware
Siemens - Simatic S7 1500 Cpu 1518 4 Pn\/dp Mfp Firmware
Siemens - Sinamics Connect 300 Firmware

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
High (H)
Conditions spécifiques doivent être réunies pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
High
Interruption totale du service possible

> HISTORIQUE DES MODIFICATIONS

Première apparition
25/03/2021 15:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:26
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME