> DESCRIPTION

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.

> AFFECTED_PRODUCTS

Siemens - Sinamics Gh150 Firmware
Siemens - Sinamics Gl150 Firmware
Siemens - Sinamics Gm150 Firmware
Siemens - Sinamics Sl150 Firmware
Siemens - Sinamics Sm120 Firmware
Siemens - Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
< 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Version: 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
< 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp400f Firmware
Version: 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
< 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Version: 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
< 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700 Firmware
Version: 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
< 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Version: 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
< 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp700f Firmware
Version: 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
< 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Version: 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
< 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900 Firmware
Version: 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
< 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Version: 16
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
< 15.1
Siemens - Simatic Hmi Ktp Mobile Panels Ktp900f Firmware
Version: 15.1
Siemens - Simatic Wincc Runtime Advanced
< 16
Siemens - Simatic Wincc Runtime Advanced
Version: 16
Siemens - Simatic Wincc Runtime Advanced
< 15.1
Siemens - Simatic Wincc Runtime Advanced
Version: 15.1
Siemens - Sinamics Sm150 Firmware
Siemens - Simatic Hmi Comfort Outdoor Panels 7\" Firmware
< 16
Siemens - Simatic Hmi Comfort Outdoor Panels 7\" Firmware
Version: 16
Siemens - Simatic Hmi Comfort Outdoor Panels 7\" Firmware
< 15.1
Siemens - Simatic Hmi Comfort Outdoor Panels 7\" Firmware
Version: 15.1
Siemens - Simatic Hmi Comfort Outdoor Panels 15\" Firmware
< 16
Siemens - Simatic Hmi Comfort Outdoor Panels 15\" Firmware
Version: 16
Siemens - Simatic Hmi Comfort Outdoor Panels 15\" Firmware
< 15.1
Siemens - Simatic Hmi Comfort Outdoor Panels 15\" Firmware
Version: 15.1
Siemens - Simatic Hmi Comfort Panels 4\" Firmware
< 16
Siemens - Simatic Hmi Comfort Panels 4\" Firmware
Version: 16
Siemens - Simatic Hmi Comfort Panels 4\" Firmware
< 15.1
Siemens - Simatic Hmi Comfort Panels 4\" Firmware
Version: 15.1
Siemens - Simatic Hmi Comfort Panels 22\" Firmware
< 16
Siemens - Simatic Hmi Comfort Panels 22\" Firmware
Version: 16
Siemens - Simatic Hmi Comfort Panels 22\" Firmware
< 15.1
Siemens - Simatic Hmi Comfort Panels 22\" Firmware
Version: 15.1
Siemens - Sinamics Sh150 Firmware
Siemens - Sinamics Sm150i Firmware

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
High
Interruption totale du service possible

> HISTORIQUE DES MODIFICATIONS

Première apparition
12/05/2021 14:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:27
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME