> CVE-2021-22924 [LOW]

« BACK_TO_HOME
PUBLISHED
2021-08-05 21:15
MODIFIED
2025-06-09 15:15
CVSS_SCORE V3
3.7
EPSS (Prob. Exploit)
6.27%
Top 6.3%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-15

> DESCRIPTION

libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate.

> AFFECTED_PRODUCTS

Debian - Debian Linux
Version: 9.0
Debian - Debian Linux
Version: 10.0
Debian - Debian Linux
Version: 11.0
Fedoraproject - Fedora
Version: 33
Haxx - Libcurl
>= 7.10.4 < 7.77.0
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.57
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.58
Oracle - Peoplesoft Enterprise Peopletools
Version: 8.59
Siemens - Sinema Remote Connect Server
< 3.1
Siemens - Scalance S615 Firmware
< 7.1
Siemens - Sinema Remote Connect
< 3.1
Siemens - Simatic Cp 1543 1 Firmware
< 3.0.22
Oracle - Mysql Server
>= 5.7.0 <= 5.7.36
Oracle - Mysql Server
>= 8.0.0 <= 8.0.26
Siemens - Sinec Infrastructure Network Services
< 1.0.1.1
Splunk - Universal Forwarder
>= 8.2.0 < 8.2.12
Splunk - Universal Forwarder
>= 9.0.0 < 9.0.6
Splunk - Universal Forwarder
Version: 9.1.0
Siemens - Logo\! Cmr2020 Firmware
Siemens - Logo\! Cmr2040 Firmware
Siemens - Simatic Rtu3031c Firmware
< 5.0.14
Siemens - Simatic Rtu3030c Firmware
< 5.0.14
Siemens - Ruggedcomrm 1224 Lte Firmware
< 7.1
Siemens - Scalance M804pb Firmware
< 7.1
Siemens - Scalance M812 1 Firmware
< 7.1
Siemens - Scalance M816 1 Firmware
< 7.1
Siemens - Scalance M826 2 Firmware
< 7.1
Siemens - Scalance M874 2 Firmware
< 7.1
Siemens - Scalance M874 3 Firmware
< 7.1
Siemens - Scalance M876 3 Firmware
< 7.1
Siemens - Scalance M876 4 Firmware
< 7.1
Siemens - Scalance Mum856 1 Firmware
< 7.1
Siemens - Simatic Cp 1545 1 Firmware
< 1.1
Siemens - Simatic Rtu3010c Firmware
< 5.0.14
Siemens - Simatic Rtu 3041c Firmware
< 5.0.14
Siemens - Siplus Net Cp 1543 1 Firmware
< 3.0.22

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
High (H)
Conditions spécifiques doivent être réunies pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
Low (L)
Divulgation limitée d'informations
I (Impact Intégrité)
Integrity Impact
None (N)
Aucune modification de données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
Low
Divulgation limitée d'informations
Intégrité
None
Aucune modification de données possible
Disponibilité
None
Aucune interruption de service

> HISTORIQUE DES MODIFICATIONS

Première apparition
05/08/2021 21:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:28
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME