> CVE-2021-22779 [CRITICAL]

« BACK_TO_HOME
PUBLISHED
2021-07-14 15:15
MODIFIED
2024-11-21 05:50
CVSS_SCORE V3
9.1
EPSS (Prob. Exploit)
1.05%
Top 35.5%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-11-08

> DESCRIPTION

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

> AFFECTED_PRODUCTS

Schneider Electric - Modicon M340 Bmxp341000 Firmware
Schneider Electric - Modicon M340 Bmxp342010 Firmware
Schneider Electric - Modicon M340 Bmxp342020 Firmware
Schneider Electric - Modicon M340 Bmxp342030 Firmware
Schneider Electric - Modicon M580 Bmep584040 Firmware
Schneider Electric - Modicon M580 Bmep586040 Firmware
Schneider Electric - Modicon M580 Bmep581020 Firmware
Schneider Electric - Modicon M580 Bmep582020 Firmware
Schneider Electric - Modicon M580 Bmep582040 Firmware
Schneider Electric - Modicon M580 Bmep583020 Firmware
Schneider Electric - Modicon M580 Bmep583040 Firmware
Schneider Electric - Modicon M580 Bmep584020 Firmware
Schneider Electric - Modicon M580 Bmep585040 Firmware
Schneider Electric - Modicon M580 Bmep582040s Firmware
Schneider Electric - Ecostruxure Control Expert
< 15.0
Schneider Electric - Ecostruxure Control Expert
Version: 15.0
Schneider Electric - Modicon M580 Bmeh584040 Firmware
Schneider Electric - Modicon M580 Bmeh586040 Firmware
Schneider Electric - Modicon M580 Bmeh582040 Firmware
Schneider Electric - Modicon M580 Bmep584040s Firmware
Schneider Electric - Modicon M580 Bmeh584040s Firmware
Schneider Electric - Modicon M580 Bmeh586040s Firmware
Schneider Electric - Ecostruxure Process Expert
Schneider Electric - Remoteconnect
Schneider Electric - Modicon M580 Bmep581020h Firmware
Schneider Electric - Modicon M580 Bmep582020h Firmware
Schneider Electric - Modicon M580 Bmep582040h Firmware
Schneider Electric - Modicon M580 Bmep585040c Firmware
Schneider Electric - Modicon M580 Bmep586040c Firmware
Schneider Electric - Modicon M580 Bmeh582040c Firmware
Schneider Electric - Modicon M580 Bmeh582040s Firmware
Schneider Electric - Modicon M580 Bmeh584040c Firmware
Schneider Electric - Modicon M580 Bmeh586040c Firmware

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
None
Aucune interruption de service

> HISTORIQUE DES MODIFICATIONS

Première apparition
14/07/2021 15:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:28
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME