> CVE-2019-5617 [CRITICAL]

« BACK_TO_HOME
PUBLISHED
2019-11-06 19:15
MODIFIED
2024-11-21 04:45
CVSS_SCORE V3
10.0
EPSS (Prob. Exploit)
1.32%
Top 29.3%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

> AFFECTED_PRODUCTS

Gatech - Computing For Good\'s Basic Laboratory Information System
<= 3.4

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Changed (C)
Impact s'étend au-delà du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
High
Interruption totale du service possible

> HISTORIQUE DES MODIFICATIONS

Première apparition
06/11/2019 19:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:20
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME