> CVE-2019-10929 [MEDIUM]

« BACK_TO_HOME
PUBLISHED
2019-08-13 19:15
MODIFIED
2024-11-21 04:20
CVSS_SCORE V3
5.9
EPSS (Prob. Exploit)
0.98%
Top 38.1%
DATA SOURCES:
NVD 🔗 2025-10-18 CVE PROJECT 🔗 2026-01-19 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC STEP 7 (TIA Portal) (All versions < V16), SIMATIC WinCC (TIA Portal) (All versions < V16), SIMATIC WinCC OA (All versions < V3.16 P013), SIMATIC WinCC Runtime Advanced (All versions < V16), SIMATIC WinCC Runtime Professional (All versions < V16), TIM 1531 IRC (incl. SIPLUS NET variants) (All versions < V2.1). Affected devices contain a message protection bypass vulnerability due to certain properties in the calculation used for integrity protection. This could allow an attacker in a Man-in-the-Middle position to modify network traffic sent on port 102/tcp to the affected devices.

> AFFECTED_PRODUCTS

Siemens - Simatic Wincc
< 16
Siemens - Simatic Wincc Runtime
Siemens - Simatic Step 7
< 16
Siemens - Simatic S7 1200 Cpu 1211c Firmware
<= 4.0
Siemens - Simatic S7 1200 Cpu 1212c Firmware
<= 4.0
Siemens - Simatic S7 1200 Cpu 1214c Firmware
<= 4.0
Siemens - Simatic S7 1200 Cpu 1215c Firmware
<= 4.0
Siemens - Simatic S7 1200 Cpu 1217c Firmware
<= 4.0
Siemens - Simatic Wincc Open Architecture
<= 3.15
Siemens - Simatic Wincc Open Architecture
Version: 3.16
Siemens - Simatic Cp 1626 Firmware
Siemens - Simatic Net Pc
< 16
Siemens - Simatic S7 Plcsim Advanced
Siemens - Simatic Et 200sp Open Controller Cpu 1515sp Pc Firmware
Siemens - Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware
Siemens - Simatic S7 1500 Cpu 1518 Firmware
Siemens - Simatic S7 1500 Cpu 1511c Firmware
Siemens - Simatic S7 1500 Cpu 1512c Firmware
Siemens - Simatic S7 1500
Siemens - Simatic Tim 1531 Irc Firmware
< 2.1
Siemens - Simatic Hmi Panel Firmware

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
High (H)
Conditions spécifiques doivent être réunies pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
None (N)
Aucune divulgation d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
None
Aucune divulgation d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
None
Aucune interruption de service

> HISTORIQUE DES MODIFICATIONS

Première apparition
13/08/2019 19:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:19
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago