> CVE-2018-25120 [CRITICAL]

« BACK_TO_HOME
PUBLISHED
2025-10-29 19:15
MODIFIED
2025-10-29 19:15
CVSS_SCORE V3
9.3
EPSS (Prob. Exploit)
9.81%
Top 4.4%
DATA SOURCES:
NVD 🔗 2025-10-29 CVE PROJECT 🔗 2026-01-19 CWE MITRE 🔗 2026-11-01 FIRST EPSS 🔗 2026-10-25

> DESCRIPTION

D-Link DNS-343 ShareCenter devices running firmware versions up to and including 1.05 contain a command injection vulnerability in the Mail Test functionality. The web maintenance script posts to the internal goForm endpoint '/goform/Mail_Test' and uses several form parameters directly in a call to a system email utility without proper input validation. An unauthenticated remote attacker can supply crafted form data that injects shell commands, resulting in execution as root on the device. NOTE: The DNS-343 product line has been declared end-of-life.

> AFFECTED_PRODUCTS

ℹ️ Aucun produit affecté n'a encore été publié par NVD pour cette CVE.

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Network (N)
Exploit possible à distance via réseau (HTTP, API, etc.)
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
High (H)
Modification totale des données possible
A (Impact Disponibilité)
Availability Impact
High (H)
Interruption totale du service possible

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
High
Modification totale des données possible
Disponibilité
High
Interruption totale du service possible

> WEAKNESSES

CWE-78

> CWE DETAILED DESCRIPTIONS

CWE-78: Improper Neutralization of Special Elements used in an OS Command - The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

> HISTORIQUE DES MODIFICATIONS

Première apparition
29/10/2025 19:15
Source: NVD
📊 ENRICHISSEMENT 01/11/2026 06:58
CWE
Champ modifié: Description CWE
Ancienne valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') - The product constructs all or part of an OS command using externally-influenced input from an upstr...
Nouvelle valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command - The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it doe...
📊 ENRICHISSEMENT 19/01/2026 17:36
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
📊 ENRICHISSEMENT 01/11/2025 06:01
CWE
Champ modifié: Description CWE
Ancienne valeur:
N/A
Nouvelle valeur:
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') - The product constructs all or part of an OS command using externally-influenced input from an upstr...
Total des modifications: 3 Dernière mise à jour: 1 week ago

> REFERENCES

https://github.com/jamesbercegay/advisories/blob/master/%5BGTSA-00128%5D%20D-Lin...
https://qkl.seebug.org/vuldb/ssvid-97088
https://www.dlink.com/al/sq/products/dns-343-sharecenter-4-bay-network-storage-e...
https://www.exploit-db.com/exploits/43845
https://www.vulncheck.com/advisories/dlink-dns343-sharecenter-command-injection-...
« BACK_TO_HOME