> DESCRIPTION

In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

> AFFECTED_PRODUCTS

Blipcare - Wi Fi Blood Pressure Monitor Firmware
<= bp700_10.1

> CVSS V3 METRICS

CVSS_VECTOR
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N

> MÉTRIQUES CVSS DÉTAILLÉES

CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N
Métrique Valeur Interprétation
AV (Vecteur d'Attaque)
Attack Vector
Adjacent (A)
Exploit nécessite un accès au segment réseau local
AC (Complexité d'Attaque)
Attack Complexity
Low (L)
Peu de conditions requises pour exploiter
PR (Privilèges Requis)
Privileges Required
None (N)
Aucune authentification requise
UI (Interaction Utilisateur)
User Interaction
None (N)
Aucune interaction utilisateur nécessaire
S (Périmètre)
Scope
Unchanged (U)
Impact reste dans le périmètre du composant compromis
C (Impact Confidentialité)
Confidentiality Impact
High (H)
Divulgation totale d'informations
I (Impact Intégrité)
Integrity Impact
Low (L)
Modification limitée des données possible
A (Impact Disponibilité)
Availability Impact
None (N)
Aucune interruption de service

> RÉSUMÉ DES IMPACTS

Confidentialité
High
Divulgation totale d'informations
Intégrité
Low
Modification limitée des données possible
Disponibilité
None
Aucune interruption de service

> HISTORIQUE DES MODIFICATIONS

Première apparition
02/07/2019 21:15
Source: NVD
📊 ENRICHISSEMENT 18/10/2025 14:12
CVEPROJECT
Champ modifié: CVE Project
Ancienne valeur:
Non
Nouvelle valeur:
Oui
Total des modifications: 1 Dernière mise à jour: 1 year ago
« BACK_TO_HOME