[MY_SUBSCRIPTIONS]

Get cybersecurity news alerts delivered to your inbox

📡 [FLUX RSS]

Subscribe to the news feed

7 derniers jours

> FILTERS

> Last 7 Days

> TODAY'S SUMMARY (103 articles)

|

// AI-powered summary generated at 16:00

> CVE-2025-53729 Microsoft Azure File Sync Elevation of Privilege Vulnerability
Improper access control in Azure File Sync allows an authorized attacker to elevate privileges locally.
> Arbitrary file overwrite in FGFMd
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability [CWE-22] in FortiManager & FortiManager Cloud may allow an authenticated remote attacker to overwrite arbitrary files via FGFM crafted requests. Revised on 2025-08-13 00:00:00
> Path traversal vulnerability in CLI
Multiple relative path traversal vulnerabilities [CWE-23] in FortiMail, FortiVoice, FortiRecorder, FortiCamera & FortiNDR may allow a privileged attacker to read files from the underlying filesystem via crafted CLI requests.  Revised on 2025-08-13 00:00:00
> Cyber security for high profile conferences
Managing the cyber security of high profile events in the real and virtual worlds.
> Authentication bypass via invalid parameter
An improper handling of parameters [CWE-233] vulnerability in FortiWeb may allow an unauthenticated remote attacker in possession of non-public information (pertaining to both the device and to the targeted user) to log in as any existing user on the device via a specially crafted request. Revised...
> Command injection in CLI
An improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability [CWE-78] in FortiWeb may allow an authenticated privileged attacker to execute unauthorized code or commands via crafted CLI commands Revised on 2025-08-12 00:00:00
> ZDI-25-830: (0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetPagesAsImages Server-Side Request Forgery Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned:...
> Command injection in CLI command
A improper neutralization of special elements used in an os command ('os command injection') vulnerability [CWE-78] in FortiWeb CLI may allow a privileged attacker to execute arbitrary code or command via crafted CLI commands. Revised on 2025-08-12 00:00:00
> Double free in automation-stitch
A double free vulnerability [CWE-415] in FortiOS, FortiProxy & FortiPAM administrative interfaces may allow a privileged attacker to execute code or commands via crafted HTTP or HTTPs requests. Revised on 2025-08-12 00:00:00
> ZDI-25-829: (0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetFilteredSinkProvider Deserialization of Untrusted Data Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 8.8. The following CVEs are assigned: CVE-2025-549...
> Incorrect Privilege Assignment in Security Fabric
An incorrect privilege assignment vulnerability [CWE-266] in FortiOS Security Fabric may allow a remote authenticated attacker with high privileges to escalate their privileges to super-admin via registering the device to a malicious FortiManager. Revised on 2025-08-12 00:00:00
> Integer Overflow on SSL-VPN bookmarks
An Integer Overflow or Wraparound vulnerability [CWE-190] in FortiOS, FortiPAM and FortiProxy SSL-VPN RDP and VNC bookmarks may allow an authenticated user to affect the device SSL-VPN availability via crafted requests. Revised on 2025-08-12 00:00:00
> ZDI-25-828: (0Day) Schneider Electric EcoStruxure Power Monitoring Expert HttpPostedFile Directory Traversal Remote Code Execution Vulnerability
This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.2. The following CVEs are assigned: CVE-2025-549...
> OS command injections via GET request parameter
An improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerability [CWE-78] in FortiADC may allow a remote and authenticated attacker with low privilege to execute unauthorized code via specifically crafted HTTP parameters. Revised on 2025-08-12 00:00:00
> Path traversal in Solution Pack upload
A relative path traversal vulnerability [CWE-23] in FortiSOAR may allow an authenticated attacker to read arbitrary files via uploading a malicious solution pack. Revised on 2025-08-12 00:00:00
> ZDI-25-827: (0Day) Schneider Electric EcoStruxure Power Monitoring Expert GetTgmlContent Directory Traversal Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 4.9. The following CVEs are assigned: CVE-...
> Remote unauthenticated command injection
An improper neutralization of special elements used in an OS command ('OS Command Injection') vulnerability [CWE-78] in FortiSIEM may allow an unauthenticated attacker to execute unauthorized code or commands via crafted CLI requests.Practical exploit code for this vulnerability was found in the wil...
> Stack buffer overflow in CLI command
A stack-based buffer overflow vulnerability [CWE-121] in FortiWeb CLI may allow a privileged attacker to execute arbitrary code or commands via crafted CLI commands Revised on 2025-08-12 00:00:00
> ZDI-25-826: (0Day) Schneider Electric EcoStruxure Power Monitoring Expert ExportDataAsXML Server-Side Request Forgery Information Disclosure Vulnerability
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Schneider Electric EcoStruxure Power Monitoring Expert. Authentication is not required to exploit this vulnerability. The ZDI has assigned a CVSS rating of 7.5. The following CVEs are assigned:...
> Weak authentication - FGFM protocol
An authentication bypass using an alternate path or channel [CWE-288] vulnerability in FortiOS, FortiProxy & FortiPAM may allow an unauthenticated attacker to seize control of a managed device via crafted FGFM requests, if the device is managed by a FortiManager, and if the attacker knows that F...